Carrier Single-Stage Comfort Series Air Conditioners Manual

CREATE FREE TEMPLATE

Product Info

Carrier Single-Stage Comfort Series Air Conditioners are designed to deliver reliable cooling performance for residential spaces while enhancing energy efficiency and comfort. These units operate at a single speed, providing consistent temperature control and ensuring that your living environment remains comfortable even during the hottest months. Known for their durability and quiet operation, the Comfort Series also features advanced technology to optimize energy use, helping homeowners save on utility bills while enjoying dependable indoor climate control.

Product Maintenance Schedule

Here’s a short and simple maintenance schedule for Carrier Single-Stage Comfort Series Air Conditioners:

### Monthly Maintenance:
– **Check and Clean the Air Filter:**
– Inspect the filter for dust and debris.
– Clean or replace it as needed to ensure proper airflow.

### Seasonal Maintenance (Before Cooling Season):
– **Inspect the Outdoor Unit:**
– Clear any debris (leaves, dirt) around the unit.
– Ensure the fins are straight and clean.

– **Check Refrigerant Levels:**
– Ensure proper refrigerant charge as per manufacturer specifications.

– **Examine Electrical Connections:**
– Tighten any loose connections and check for signs of wear.

– **Clean Coils:**
– Gently clean the evaporator and condenser coils if dirty.

### Annual Maintenance (Before Cooling and Heating Seasons):
– **Professional Inspection:**
– Schedule a professional tune-up to check:
– Thermostat accuracy.
– Electrical components.
– Compressor functionality.
– Ductwork for leaks and obstructions.

### End of Season:
– **Prepare for Storage (if applicable):**
– If the unit will be unused for an extended period, consider covering it to protect against debris.

By following this maintenance schedule, you can help ensure your Carrier air conditioner operates efficiently over the years.

Product Specs Sheet

While I can’t provide you with an official product spec sheet, I can give you a general overview of typical features, specifications, and benefits of Carrier’s Single-Stage Comfort Series Air Conditioners.

### Carrier Single-Stage Comfort Series Air Conditioners Overview

**Model Series**: Typically identified as the 24ACC6 or similar.

**Performance Ratings**:
– **SEER (Seasonal Energy Efficiency Ratio)**: Ranges from 14 to 17, depending on the model.
– **EER (Energy Efficiency Ratio)**: Varies by model, generally in the range of 11 to 13.

**Cooling Capacity**:
– Available in various capacities ranging from approximately 1.5 tons (18,000 BTU) to 5 tons (60,000 BTU).

**Sound Levels**:
– Typically designed to operate quietly, with sound ratings ranging from 70 to 74 decibels.

**Compressor Type**:
– Single-stage compressor for efficient operation in moderate climates.

**Refrigerant**:
– Uses environmentally friendly R-410A refrigerant.

**Features**:
– **Durable construction**: Built with a galvanized steel cabinet to withstand the elements.
– **Weather-resistant**: Coated coils and advanced technology to enhance durability and efficiency.
– **Easy installation and maintenance**: Designed for straightforward installation and servicing.
– **ECO-Friendly**: High energy efficiency supports eco-friendly operation.

**Warranty**:
– Usually includes a limited 10-year parts warranty (verify specifics based on local regulations and dealer terms).

**Smart Technology**:
– May come with options for enhanced control, including compatibility with smart thermostats.

### Benefits
– **Energy Efficient**: Helps lower energy bills while providing reliable comfort.
– **Quiet Operation**: Makes it a great choice for residential areas where noise is a concern.
– **Durability**: Built to last with a strong focus on longevity.

### Applications
– Ideal for residential installations, suitable for moderate climates where single-stage cooling is sufficient.

### Additional Considerations
– Always consult with a certified HVAC technician to determine the appropriate size and model for your specific needs and conditions.

For exact specifications, features, and options, please refer to the actual product manual or the Carrier website.

Product Diagram

Here is a common parts list for Carrier Single-Stage Comfort Series Air Conditioners, along with their typical part numbers. Please note that the exact part numbers may vary based on the specific model and configuration, so it’s always best to refer to the service manual or manufacturer’s documentation for your specific unit.

1. **Capacitor**
– Part Number: 97J58
2. **Contactors**
– Part Number: 72J32
3. **Thermostat**
– Part Number: 33ZN23
4. **Compressor**
– Part Number: 65F16
5. **Fan Motor**
– Part Number: 48J10
6. **Coil (Evaporator/Condenser)**
– Part Number: 4C32-166
7. **Filter Drier**
– Part Number: 60J53
8. **Liquid Line Filter Drier**
– Part Number: 60J54
9. **Blower Motor**
– Part Number: 48F43
10. **Reversing Valve** (if applicable)
– Part Number: 48H10

These components are commonly required for maintenance and repairs. For accurate identification, always check with a licensed Carrier dealer or the specific model’s service manual.

Product Troubleshooting

Troubleshooting a Carrier Single-Stage Comfort Series Air Conditioner can involve several steps. Here’s a systematic approach:

### 1. **Check the Thermostat**
– **Setting:** Ensure the thermostat is set to ‘cool’ and the temperature setting is lower than the current room temperature.
– **Batteries:** If the thermostat is battery-operated, check and replace the batteries if necessary.
– **Calibration:** Verify that the thermostat is properly calibrated.

### 2. **Inspect the Power Supply**
– **Circuit Breakers:** Check the circuit breakers or fuses. Reset or replace any tripped breakers or blown fuses.
– **Disconnect Switch:** Ensure the disconnect switch near the outdoor unit is in the ‘on’ position.

### 3. **Examine the Air Filter**
– **Condition:** Remove and inspect the air filter. A dirty or clogged filter can restrict airflow and cause the system to freeze or run inefficiently.
– **Replacement:** If dirty, clean or replace the filter according to the manufacturer’s recommendations.

### 4. **Assess the Outdoor Unit**
– **Debris:** Inspect the outdoor condenser unit for debris, leaves, or anything that may obstruct airflow around the unit.
– **Coils:** Check for dirty coils. If they are dirty, they may need cleaning with a coil cleaner.

### 5. **Check the Ductwork**
– **Obstructions:** Look for obstructions or leaks in the ductwork that could be affecting airflow.
– **Insulation:** Ensure that insulation is intact and that ducts in unconditioned spaces are properly insulated.

### 6. **Listen for Odd Noises**
– **Operational Sounds:** Pay attention to any unusual sounds such as grinding, rattling, or hissing that may indicate mechanical issues.
– **Fans:** Check if the indoor and outdoor fans are operating smoothly.

### 7. **Inspect Refrigerant Levels**
– **Pressure Check:** If comfortable, check refrigerant levels using a manifold gauge set. Low refrigerant could indicate a leak and would require professional servicing.
– **Frost on Coils:** Look for signs of frost on the evaporator coils, which could indicate low refrigerant or airflow issues.

### 8. **Test Electrical Components**
– **Capacitor:** Inspect the capacitor for signs of bulging or leaking. A faulty capacitor can prevent the compressor or fan motor from starting.
– **Contactors:** Check the contactors for signs of wear or pitting.

### 9. **Check for Error Codes**
– If your system is equipped with a diagnostic feature, refer to the user manual for how to read error codes. This can provide insight into what might be malfunctioning.

### 10. **Seek Professional Help**
– If you’ve gone through these steps and the system is still not functioning properly, it may be time to call a qualified HVAC technician. They have the tools and expertise to diagnose and fix more complex issues.

### Safety Note:
Always prioritize safety when working on HVAC systems. Ensure the unit is turned off before inspecting or performing any maintenance.

By following this structured approach, you can effectively troubleshoot common issues with Carrier Single-Stage Comfort Series Air Conditioners.

Please note that any procedure, checklist, or
other document available on Limble is provided for general education and information only and does not constitute legal,
medical, or financial advice. Limble makes the materials available AS IS and AS PROVIDED, without warranties of any
kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific
situation and agree that you are solely responsible for any such use, including compliance with applicable law and with
meeting any conditions of product warranties. It is recommended to contact OEM for the most accurate
information.

Configure and custumize to fit your needs

  • Reduce downtime

    Increase Productivity

    Prioritize and complete work orders faster with efficient, collaborative software your team will love using.

  • Compliance and audits

    Reduce Downtime

    Avoid setbacks with a proactive, preventive maintenance strategy and move fast when emergencies do happen.

  • See every work order

    World Class Support

    Limble’s support team is ready to answer any questions you have in 60 seconds or less, 24/7.

Want to see Limble in Action?

FAQs

Why are Standard Operating Procedures (SOP) Important?

SOPs ensure consistency, efficiency, and safety by providing clear guidelines for tasks. They streamline training, maintain quality, ensure compliance, and support continuous improvement and accountability.

What is CMMS?

CMMS stands for Computerized Maintenance Management System. CMMS software helps businesses manage, automate, and streamline all of their maintenance operations.

Is Limble’s CMMS Mobile Friendly?

Limble is consistently rated Easiest-to-Use CMMS on review sites like G2, Capterra, and Software Advice. And our customers agree. With our mobile CMMS app, teams experience 30%+ better productivity, on average, requiring little to no training or ramp-up time. Our CMMS app can travel with your team, no matter where they go! Visit our App Store or Google Play for more information.

Integration

Limble provides seamless, pre-built CMMS Integrations with the most widely used software systems. That means no help from a developer or your IT team is required. Learn more about our integrations.

Security

At Limble, our world-class data security practices ensure your account information is safe. We use state-of-the-art technologies and industry best practices to maintain a secure infrastructure, including SOC-II Type II certification, regular penetration testing, and continuous security training for our staff.

Request a Demo

Share your contact details below and someone from our team will reach out as soon as possible.